<?xml version='1.0' encoding='UTF-8'?><rss xmlns:atom='http://www.w3.org/2005/Atom' xmlns:openSearch='http://a9.com/-/spec/opensearchrss/1.0/' xmlns:georss='http://www.georss.org/georss' xmlns:gd='http://schemas.google.com/g/2005' xmlns:thr='http://purl.org/syndication/thread/1.0' version='2.0'><channel><atom:id>tag:blogger.com,1999:blog-5812867464294190346</atom:id><lastBuildDate>Fri, 17 Feb 2012 04:55:28 +0000</lastBuildDate><title>PLC INSTALLATION</title><description>This article explains how to install a Programmable Logic Controller</description><link>http://plc-installation.blogspot.com/</link><managingEditor>noreply@blogger.com (AGUNG)</managingEditor><generator>Blogger</generator><openSearch:totalResults>6</openSearch:totalResults><openSearch:startIndex>1</openSearch:startIndex><openSearch:itemsPerPage>25</openSearch:itemsPerPage><item><guid isPermaLink='false'>tag:blogger.com,1999:blog-5812867464294190346.post-7535000100007950390</guid><pubDate>Thu, 13 Mar 2008 00:30:00 +0000</pubDate><atom:updated>2010-11-07T22:53:02.827+08:00</atom:updated><title>Checking the work and making the report</title><description>&lt;div align="justify"&gt;&lt;span style="font-family: arial;"&gt;&lt;b&gt;Inspecting installation&lt;/b&gt;&lt;br /&gt;After Installation has been done then done inspection of the work quality and wiring. This matter is executed by checking every extension cables at devices and compared with the wiring diagram which has been prepared. Checking extension cables and devices are done by using the assistive equipment like the multimeter and testpen. &lt;/span&gt;&lt;/div&gt;&lt;div align="justify"&gt;&lt;span style="font-family: arial;"&gt;Matters which require to be paid attention to in inspection for example:&lt;/span&gt;&lt;/div&gt;&lt;ul&gt;&lt;li&gt;&lt;div align="justify"&gt;&lt;span style="font-family: arial;"&gt;Whether all Units of the PLC&lt;img alt="" border="0" height="1" src="http://www.assoc-amazon.com/e/ir?t=pi0fa-20&amp;amp;l=btl&amp;amp;camp=213689&amp;amp;creative=392969&amp;amp;o=1&amp;amp;a=B001DIL6WY" style="border: medium none ! important; margin: 0px ! important; padding: 0px ! important;" width="1" /&gt; and I/O devices have been attached truly?&lt;/span&gt;&lt;/div&gt;&lt;/li&gt;&lt;li&gt;&lt;div align="justify"&gt;&lt;span style="font-family: arial;"&gt;Whether all cables and connectors have been attached compactly according to the wiring diagram and jam in lickety split?&lt;/span&gt;&lt;/div&gt;&lt;/li&gt;&lt;li&gt;&lt;div align="justify"&gt;&lt;span style="font-family: arial;"&gt;Are there Loose terminal screws?&lt;/span&gt;&lt;/div&gt;&lt;/li&gt;&lt;li&gt;&lt;div align="justify"&gt;&lt;span style="font-family: arial;"&gt;Are there Loose connectors?&lt;/span&gt;&lt;/div&gt;&lt;/li&gt;&lt;/ul&gt;&lt;div align="justify"&gt;&lt;br /&gt;&lt;span style="font-family: arial;"&gt;&lt;b&gt;Testing installation&lt;/b&gt;&lt;br /&gt;Several items which require to be tested in installation of the PLC for example;&lt;/span&gt;&lt;/div&gt;&lt;div align="justify"&gt;&lt;span style="font-family: arial;"&gt;&lt;i&gt;Wiring input&lt;br /&gt;&lt;/i&gt;Wiring input can be tested by connecting all input devices and see the indicator lamp on Input Units of the PLC. Wiring input of the PLC can be told goodness if the indicator lamp on Input Units is ON.&lt;/span&gt;&lt;/div&gt;&lt;div align="justify"&gt;&lt;span style="font-family: Arial;"&gt;&lt;/span&gt;&lt;/div&gt;&lt;div align="justify"&gt;&lt;span style="font-family: arial;"&gt;&lt;i&gt;&lt;/i&gt;&lt;/span&gt;&lt;/div&gt;&lt;div align="justify"&gt;&lt;span style="font-family: arial;"&gt;&lt;i&gt;Wiring output&lt;/i&gt;&lt;br /&gt;Wiring output can be tested by using force instruction to output terminal of the PLC. The instruction can be used without waiting the program has been made and can be separated without damage the existing program if the PLC has been programmed.&lt;/span&gt;&lt;/div&gt;&lt;div align="justify"&gt;&lt;span style="font-family: arial;"&gt;The following example show forcing at the Omron PLC;&lt;/span&gt;&lt;/div&gt;&lt;ul&gt;&lt;li&gt;&lt;div align="justify"&gt;&lt;span style="font-family: arial;"&gt;Connect the Programming Console, set the mode switch to PROGRAM mode, and turn ON the PLC&lt;/span&gt; &lt;/div&gt;&lt;/li&gt;&lt;/ul&gt;&lt;ul&gt;&lt;li&gt;&lt;div align="justify"&gt;&lt;span style="font-family: arial;"&gt;Enter the password by press&lt;br /&gt;&lt;a href="http://3.bp.blogspot.com/__O36vLCsD3k/R9h3mFdQuZI/AAAAAAAAANU/Jrf6zMzGxkM/s1600-h/Clip_3.jpg"&gt;&lt;span style="font-family: arial;"&gt;&lt;img alt="" border="0" height="51" id="BLOGGER_PHOTO_ID_5177019267846027666" src="http://3.bp.blogspot.com/__O36vLCsD3k/R9h3mFdQuZI/AAAAAAAAANU/Jrf6zMzGxkM/s400/Clip_3.jpg" style="height: 41px; width: 223px;" width="223" /&gt;&lt;/span&gt;&lt;/a&gt;&lt;/span&gt;&lt;/div&gt;&lt;/li&gt;&lt;/ul&gt;&lt;ul&gt;&lt;li&gt;&lt;div align="justify"&gt;&lt;span style="font-family: arial;"&gt;Enter the force instruction by press&lt;br /&gt;&lt;a href="http://4.bp.blogspot.com/__O36vLCsD3k/R9h3bVdQuYI/AAAAAAAAANM/yWbQqvzCOgw/s1600-h/Clip_2.jpg"&gt;&lt;span style="font-family: arial;"&gt;&lt;img alt="" border="0" height="55" id="BLOGGER_PHOTO_ID_5177019083162433922" src="http://4.bp.blogspot.com/__O36vLCsD3k/R9h3bVdQuYI/AAAAAAAAANM/yWbQqvzCOgw/s400/Clip_2.jpg" style="height: 55px; width: 358px;" width="377" /&gt;&lt;/span&gt;&lt;/a&gt;&lt;/span&gt;&lt;/div&gt;&lt;/li&gt;&lt;/ul&gt;&lt;div align="justify"&gt;&lt;span style="font-family: arial;"&gt;&lt;/span&gt;&lt;/div&gt;&lt;div align="justify"&gt;&lt;span style="font-family: arial;"&gt;see the picture below;&lt;/span&gt;&lt;/div&gt;&lt;div align="center"&gt;&lt;a href="http://2.bp.blogspot.com/__O36vLCsD3k/R9h2q1dQuXI/AAAAAAAAANE/Uk0DIBuNvhM/s1600-h/Clip.jpg"&gt;&lt;span style="font-family: arial;"&gt;&lt;img alt="" border="0" id="BLOGGER_PHOTO_ID_5177018249938778482" src="http://2.bp.blogspot.com/__O36vLCsD3k/R9h2q1dQuXI/AAAAAAAAANE/Uk0DIBuNvhM/s400/Clip.jpg" /&gt;&lt;/span&gt;&lt;/a&gt;&lt;/div&gt;&lt;div align="center"&gt;&lt;span style="font-family: arial;"&gt;Forcing instruction&lt;br /&gt;&lt;/span&gt;&lt;/div&gt;&lt;div align="justify"&gt;&lt;br /&gt;&lt;br /&gt;&lt;/div&gt;&lt;div align="justify"&gt;&lt;span style="font-family: arial;"&gt;&lt;i&gt;&lt;/i&gt;&lt;/span&gt;&lt;/div&gt;&lt;div align="justify"&gt;&lt;span style="font-family: arial;"&gt;&lt;i&gt;Grounding resistance, Insulation resistance, Polarity&lt;/i&gt;&lt;br /&gt;Grounding resistance, and polarity can be tested by using the Multimeter while insulation resistance can be tested by using the Mega ohmmeter. For the grounding resistance has to less than 100 ohm, for the insulation resistance has to more than 1 Megaohm/volt. The polarity of DC voltage require to be retested to prevent the happening of inversed polarity which can destroy the equipments. &lt;/span&gt;&lt;/div&gt;&lt;span style="font-family: arial;"&gt;&lt;div align="justify"&gt;&lt;/div&gt;&lt;div align="justify"&gt;&lt;br /&gt;&lt;b&gt;Making the report&lt;/b&gt;&lt;br /&gt;The report is made for documentation. With the good documentation and depository of the good administration peripheral, we will be more easy to look for the archives nor things which we need.&lt;/div&gt;&lt;/span&gt;&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/5812867464294190346-7535000100007950390?l=plc-installation.blogspot.com' alt='' /&gt;&lt;/div&gt;</description><link>http://plc-installation.blogspot.com/2008/03/checking-work-and-making-report.html</link><author>noreply@blogger.com (AGUNG)</author><media:thumbnail xmlns:media='http://search.yahoo.com/mrss/' url='http://3.bp.blogspot.com/__O36vLCsD3k/R9h3mFdQuZI/AAAAAAAAANU/Jrf6zMzGxkM/s72-c/Clip_3.jpg' height='72' width='72'/></item><item><guid isPermaLink='false'>tag:blogger.com,1999:blog-5812867464294190346.post-403639704887239903</guid><pubDate>Wed, 12 Mar 2008 06:40:00 +0000</pubDate><atom:updated>2010-11-07T22:52:09.787+08:00</atom:updated><title>Steps for installing the PLC</title><description>&lt;div align="justify"&gt;&lt;span style="font-family: arial;"&gt;Following these steps for installing the PLC&lt;img alt="" border="0" height="1" src="http://www.assoc-amazon.com/e/ir?t=pi0fa-20&amp;amp;l=btl&amp;amp;camp=213689&amp;amp;creative=392969&amp;amp;o=1&amp;amp;a=1594603316" style="border: medium none ! important; margin: 0px ! important; padding: 0px ! important;" width="1" /&gt;:&lt;/span&gt;&lt;/div&gt;&lt;div align="justify"&gt;&lt;span style="font-family: arial;"&gt;&lt;b&gt;&lt;/b&gt;&lt;/span&gt;&lt;/div&gt;&lt;div align="justify"&gt;&lt;span style="font-family: arial;"&gt;&lt;b&gt;1. Panel/Cabinet Installation&lt;/b&gt;&lt;br /&gt;Consider PLC operation, maintenance, and surrounding conditions when installing the PLC in a panel or cabinet.&lt;br /&gt;The operating temperature range for the PLC is 0°C to 55°C Be sure that there is adequate ventilation for cooling;&lt;/span&gt;&lt;/div&gt;&lt;ul&gt;&lt;li&gt;&lt;div align="justify"&gt;&lt;span style="font-family: arial;"&gt;Allow enough space for air circulation. &lt;/span&gt;&lt;/div&gt;&lt;/li&gt;&lt;li&gt;&lt;div align="justify"&gt;&lt;span style="font-family: arial;"&gt;Do not install the PLC above equipment that generates a large amount of heat, such as heaters, transformers, or large resistors. &lt;/span&gt;&lt;/div&gt;&lt;/li&gt;&lt;li&gt;&lt;div align="justify"&gt;&lt;span style="font-family: arial;"&gt;Install a cooling fan or system when the ambient temperature exceeds 55°C&lt;br /&gt;&lt;/span&gt;&lt;/div&gt;&lt;/li&gt;&lt;/ul&gt;&lt;span style="font-family: arial;"&gt;See the picture below;&lt;br /&gt;&lt;/span&gt;&lt;br /&gt;&lt;div align="justify"&gt;&lt;br /&gt;&lt;/div&gt;&lt;div align="center"&gt;&lt;a href="http://4.bp.blogspot.com/__O36vLCsD3k/R9fKVldQuWI/AAAAAAAAAM8/h8n0bXXEM4U/s1600-h/Clip_32.jpg"&gt;&lt;span style="font-family: arial;"&gt;&lt;img alt="" border="0" id="BLOGGER_PHOTO_ID_5176828768866580834" src="http://4.bp.blogspot.com/__O36vLCsD3k/R9fKVldQuWI/AAAAAAAAAM8/h8n0bXXEM4U/s400/Clip_32.jpg" /&gt;&lt;/span&gt;&lt;/a&gt;&lt;/div&gt;&lt;div align="center"&gt;&lt;span style="font-family: arial;"&gt;The small PLC in panel&lt;/span&gt;&lt;/div&gt;&lt;div align="center"&gt;&lt;br /&gt;&lt;/div&gt;&lt;div align="center"&gt;&lt;a href="http://2.bp.blogspot.com/__O36vLCsD3k/R9fKIFdQuVI/AAAAAAAAAM0/tZzB52Q0v9E/s1600-h/Clip_31.jpg"&gt;&lt;span style="font-family: arial;"&gt;&lt;img alt="" border="0" id="BLOGGER_PHOTO_ID_5176828536938346834" src="http://2.bp.blogspot.com/__O36vLCsD3k/R9fKIFdQuVI/AAAAAAAAAM0/tZzB52Q0v9E/s400/Clip_31.jpg" /&gt;&lt;/span&gt;&lt;/a&gt;&lt;/div&gt;&lt;div align="center"&gt;&lt;span style="font-family: arial;"&gt;The big PLC in panel&lt;/span&gt;&lt;/div&gt;&lt;div align="justify"&gt;&lt;span style="font-family: arial;"&gt;&lt;/span&gt;&lt;/div&gt;&lt;div align="justify"&gt;&lt;span style="font-family: arial;"&gt;Power lines &amp;amp; high-voltage equipment can cause electrical noise in the PLC; &lt;/span&gt;&lt;/div&gt;&lt;span style="font-family: arial;"&gt;&lt;ul&gt;&lt;li&gt;Do not install the PLC in a panel or cabinet with high-voltage equipment &lt;/li&gt;&lt;li&gt;Allow at least 200 mm between the PLC and nearby power lines&lt;/li&gt;&lt;/ul&gt;&lt;br /&gt;See the picture below;&lt;br /&gt;&lt;/span&gt;&lt;br /&gt;&lt;div align="center"&gt;&lt;a href="http://2.bp.blogspot.com/__O36vLCsD3k/R9fJ2FdQuUI/AAAAAAAAAMs/Tuhrzh5tse4/s1600-h/Clip_30.jpg"&gt;&lt;span style="font-family: arial;"&gt;&lt;img alt="" border="0" id="BLOGGER_PHOTO_ID_5176828227700701506" src="http://2.bp.blogspot.com/__O36vLCsD3k/R9fJ2FdQuUI/AAAAAAAAAMs/Tuhrzh5tse4/s400/Clip_30.jpg" /&gt;&lt;/span&gt;&lt;/a&gt;&lt;/div&gt;&lt;div align="justify"&gt;&lt;span style="font-family: arial;"&gt;&lt;br /&gt;&lt;/span&gt;&lt;/div&gt;&lt;div align="justify"&gt;&lt;span style="font-family: arial;"&gt;Ensure that the PLC can be accessed for normal operation and maintenance;&lt;/span&gt;&lt;/div&gt;&lt;ul&gt;&lt;li&gt;&lt;div align="justify"&gt;&lt;span style="font-family: arial;"&gt;Provide a clear path to the PLC for operation and maintenance. High-voltage equipment or power lines could be dangerous if they are in the way during routine operations &lt;/span&gt;&lt;/div&gt;&lt;/li&gt;&lt;li&gt;&lt;div align="justify"&gt;&lt;span style="font-family: arial;"&gt;The PLC will be easiest to access if the panel or cabinet is installed about 3 to 5 feet above the floor &lt;/span&gt;&lt;/div&gt;&lt;/li&gt;&lt;/ul&gt;&lt;div align="justify"&gt;&lt;span style="font-family: arial;"&gt;&lt;/span&gt;&lt;/div&gt;&lt;span style="font-family: arial;"&gt;&lt;div align="justify"&gt;&lt;br /&gt;&lt;b&gt;2. Installing the CPU Unit &amp;amp; I/O Unit &lt;/b&gt;&lt;br /&gt;The small PLC must be installed in the position shown below to ensure adequate cooling. &lt;/div&gt;&lt;div align="justify"&gt;See the picture below;&lt;/div&gt;&lt;/span&gt;&lt;br /&gt;&lt;div align="center"&gt;&lt;a href="http://2.bp.blogspot.com/__O36vLCsD3k/R9fJjFdQuTI/AAAAAAAAAMk/VYPdj065J38/s1600-h/Clip_29.jpg"&gt;&lt;span style="font-family: arial;"&gt;&lt;img alt="" border="0" id="BLOGGER_PHOTO_ID_5176827901283186994" src="http://2.bp.blogspot.com/__O36vLCsD3k/R9fJjFdQuTI/AAAAAAAAAMk/VYPdj065J38/s400/Clip_29.jpg" /&gt;&lt;/span&gt;&lt;/a&gt;&lt;/div&gt;&lt;span style="font-family: arial;"&gt;&lt;br /&gt;&lt;/span&gt;&lt;br /&gt;&lt;span style="font-family: arial;"&gt;Do not install the small PLC in either of the following positions.&lt;br /&gt;&lt;br /&gt;&lt;/span&gt;&lt;br /&gt;&lt;div align="center"&gt;&lt;a href="http://4.bp.blogspot.com/__O36vLCsD3k/R9fJWldQuSI/AAAAAAAAAMc/IlaziJmO7bw/s1600-h/Clip_28.jpg"&gt;&lt;span style="font-family: arial;"&gt;&lt;img alt="" border="0" id="BLOGGER_PHOTO_ID_5176827686534822178" src="http://4.bp.blogspot.com/__O36vLCsD3k/R9fJWldQuSI/AAAAAAAAAMc/IlaziJmO7bw/s400/Clip_28.jpg" /&gt;&lt;/span&gt;&lt;/a&gt;&lt;/div&gt;&lt;div align="center"&gt;&lt;/div&gt;&lt;div align="justify"&gt;&lt;span style="font-family: arial;"&gt;&lt;/span&gt;&lt;/div&gt;&lt;div align="justify"&gt;&lt;span style="font-family: arial;"&gt;The small PLC can be installed on a horizontal surface or on a DIN track. See the picture below;&lt;br /&gt;&lt;/span&gt;&lt;/div&gt;&lt;div align="center"&gt;&lt;a href="http://3.bp.blogspot.com/__O36vLCsD3k/R9fJMVdQuRI/AAAAAAAAAMU/ip4cEqYrAAA/s1600-h/Clip_27.jpg"&gt;&lt;span style="font-family: arial;"&gt;&lt;img alt="" border="0" id="BLOGGER_PHOTO_ID_5176827510441163026" src="http://3.bp.blogspot.com/__O36vLCsD3k/R9fJMVdQuRI/AAAAAAAAAMU/ip4cEqYrAAA/s400/Clip_27.jpg" /&gt;&lt;/span&gt;&lt;/a&gt;&lt;/div&gt;&lt;div align="center"&gt;&lt;/div&gt;&lt;div align="justify"&gt;&lt;span style="font-family: arial;"&gt;&lt;/span&gt;&lt;/div&gt;&lt;div align="justify"&gt;&lt;span style="font-family: arial;"&gt;Lower the small PLC so that the notch on the back of the PLC catches the top of the DIN Track. Push the PC forward until the lock snaps into place. See the picture below;&lt;br /&gt;&lt;/span&gt;&lt;/div&gt;&lt;div align="center"&gt;&lt;a href="http://3.bp.blogspot.com/__O36vLCsD3k/R9fI4VdQuQI/AAAAAAAAAMM/wxKP_KNrR7k/s1600-h/Clip_26.jpg"&gt;&lt;span style="font-family: arial;"&gt;&lt;img alt="" border="0" id="BLOGGER_PHOTO_ID_5176827166843779330" src="http://3.bp.blogspot.com/__O36vLCsD3k/R9fI4VdQuQI/AAAAAAAAAMM/wxKP_KNrR7k/s400/Clip_26.jpg" /&gt;&lt;/span&gt;&lt;/a&gt;&lt;/div&gt;&lt;div align="center"&gt;&lt;/div&gt;&lt;div align="justify"&gt;&lt;span style="font-family: arial;"&gt;&lt;/span&gt;&lt;/div&gt;&lt;div align="justify"&gt;&lt;span style="font-family: arial;"&gt;For the big PLC before installing, the Units have to compiled one by one. There is no single Unit that can be said to constitute a Rack PLC. To build a Rack PLC, we start with a Backplane. The Backplane for the Omron PLC is shown below.&lt;br /&gt;&lt;/span&gt;&lt;/div&gt;&lt;div align="justify"&gt;&lt;/div&gt;&lt;div align="center"&gt;&lt;a href="http://1.bp.blogspot.com/__O36vLCsD3k/R9fIn1dQuPI/AAAAAAAAAME/NvtPoglUYyQ/s1600-h/Clip_25.jpg"&gt;&lt;span style="font-family: arial;"&gt;&lt;img alt="" border="0" id="BLOGGER_PHOTO_ID_5176826883375937778" src="http://1.bp.blogspot.com/__O36vLCsD3k/R9fIn1dQuPI/AAAAAAAAAME/NvtPoglUYyQ/s400/Clip_25.jpg" /&gt;&lt;/span&gt;&lt;/a&gt;&lt;/div&gt;&lt;div align="center"&gt;&lt;/div&gt;&lt;div align="justify"&gt;&lt;span style="font-family: arial;"&gt;&lt;/span&gt;&lt;/div&gt;&lt;div align="justify"&gt;&lt;span style="font-family: arial;"&gt;The Backplane is a simple device having two functions. The first is to provide physical support for the Units to be mounted to it. The second is to provide the connectors and electrical pathways necessary for connecting the Units mounted to it. The core of the PLC is the CPU. The CPU contains the program consisting of the series of steps necessary for the control task. The CPU has a built-in power supply, and fits into the rightmost position of the Backplane.&lt;br /&gt;&lt;/span&gt;&lt;/div&gt;&lt;div align="center"&gt;&lt;a href="http://1.bp.blogspot.com/__O36vLCsD3k/R9fIc1dQuOI/AAAAAAAAAL8/5I4HHeXvK-c/s1600-h/Clip_24.jpg"&gt;&lt;span style="font-family: arial;"&gt;&lt;img alt="" border="0" id="BLOGGER_PHOTO_ID_5176826694397376738" src="http://1.bp.blogspot.com/__O36vLCsD3k/R9fIc1dQuOI/AAAAAAAAAL8/5I4HHeXvK-c/s400/Clip_24.jpg" /&gt;&lt;/span&gt;&lt;/a&gt;&lt;/div&gt;&lt;div align="center"&gt;&lt;/div&gt;&lt;div align="justify"&gt;&lt;span style="font-family: arial;"&gt;&lt;/span&gt;&lt;/div&gt;&lt;div align="justify"&gt;&lt;span style="font-family: arial;"&gt;The CPU of the big PLC has no I/O points built in. So, in order to complete the PLC we need to mount one or more I/O Units to the Backplane. Mount the I/O Unit to the Backplane by locking the top of the I/O Unit into the slot on the Backplane and rotating the I/O Unit downwards as shown in the following diagram. Press down on the yellow tab at the bottom of the slot, press the I/O Unit firmly into position, and then release the yellow tab.&lt;br /&gt;&lt;br /&gt;&lt;/span&gt;&lt;/div&gt;&lt;div align="justify"&gt;&lt;/div&gt;&lt;div align="center"&gt;&lt;a href="http://2.bp.blogspot.com/__O36vLCsD3k/R9fIMFdQuNI/AAAAAAAAAL0/D14Io43ubQg/s1600-h/Clip_23.jpg"&gt;&lt;span style="font-family: arial;"&gt;&lt;img alt="" border="0" id="BLOGGER_PHOTO_ID_5176826406634567890" src="http://2.bp.blogspot.com/__O36vLCsD3k/R9fIMFdQuNI/AAAAAAAAAL0/D14Io43ubQg/s400/Clip_23.jpg" /&gt;&lt;/span&gt;&lt;/a&gt;&lt;/div&gt;&lt;div align="center"&gt;&lt;/div&gt;&lt;span style="font-family: arial;"&gt;&lt;/span&gt;&lt;br /&gt;&lt;div align="justify"&gt;&lt;span style="font-family: arial;"&gt;&lt;/span&gt;&lt;/div&gt;&lt;div align="justify"&gt;&lt;span style="font-family: arial;"&gt;The figure below shows one I/O Unit mounted directly to the left of the CPU.&lt;br /&gt;&lt;/span&gt;&lt;/div&gt;&lt;div align="justify"&gt;&lt;/div&gt;&lt;div align="center"&gt;&lt;a href="http://3.bp.blogspot.com/__O36vLCsD3k/R9eGXVdQuKI/AAAAAAAAALc/xfdfgy6mlqc/s1600-h/Clip_22.jpg"&gt;&lt;span style="font-family: arial;"&gt;&lt;img alt="" border="0" id="BLOGGER_PHOTO_ID_5176754032140662946" src="http://3.bp.blogspot.com/__O36vLCsD3k/R9eGXVdQuKI/AAAAAAAAALc/xfdfgy6mlqc/s400/Clip_22.jpg" /&gt;&lt;/span&gt;&lt;/a&gt;&lt;/div&gt;&lt;div align="center"&gt;&lt;/div&gt;&lt;div align="justify"&gt;&lt;span style="font-family: arial;"&gt;&lt;/span&gt;&lt;/div&gt;&lt;div align="justify"&gt;&lt;span style="font-family: arial;"&gt;I/O Units are where the control connections are made from the PLC to all the various input devices and output devices. As you can see from the figure above, there is still some space available on the left side of the Backplane. This space is for any additional I/O Units that may be required.The figure below shows a total of eight I/O Units mounted to the Backplane.&lt;br /&gt;&lt;/span&gt;&lt;/div&gt;&lt;div align="justify"&gt;&lt;/div&gt;&lt;div align="center"&gt;&lt;a href="http://3.bp.blogspot.com/__O36vLCsD3k/R9eGNVdQuJI/AAAAAAAAALU/In0vfGaJ7UQ/s1600-h/Clip_21.jpg"&gt;&lt;span style="font-family: arial;"&gt;&lt;img alt="" border="0" id="BLOGGER_PHOTO_ID_5176753860341971090" src="http://3.bp.blogspot.com/__O36vLCsD3k/R9eGNVdQuJI/AAAAAAAAALU/In0vfGaJ7UQ/s400/Clip_21.jpg" /&gt;&lt;/span&gt;&lt;/a&gt;&lt;/div&gt;&lt;div align="center"&gt;&lt;/div&gt;&lt;div align="justify"&gt;&lt;span style="font-family: arial;"&gt;&lt;/span&gt;&lt;/div&gt;&lt;div align="justify"&gt;&lt;span style="font-family: arial;"&gt;After the big PLC compiled in the backplane then the big PLC can be installed on the DIN Rail. The DIN Rail Mounting Bracket shown below is necessary for mounting the PLC to the DIN Rail.&lt;br /&gt;&lt;/span&gt;&lt;/div&gt;&lt;div align="center"&gt;&lt;a href="http://1.bp.blogspot.com/__O36vLCsD3k/R9eF_1dQuII/AAAAAAAAALM/jAomf-SLpGA/s1600-h/Clip_20.jpg"&gt;&lt;span style="font-family: arial;"&gt;&lt;img alt="" border="0" id="BLOGGER_PHOTO_ID_5176753628413737090" src="http://1.bp.blogspot.com/__O36vLCsD3k/R9eF_1dQuII/AAAAAAAAALM/jAomf-SLpGA/s400/Clip_20.jpg" /&gt;&lt;/span&gt;&lt;/a&gt;&lt;/div&gt;&lt;div align="center"&gt;&lt;/div&gt;&lt;div align="justify"&gt;&lt;span style="font-family: arial;"&gt;&lt;/span&gt;&lt;/div&gt;&lt;div align="justify"&gt;&lt;span style="font-family: arial;"&gt;&lt;/span&gt;&lt;/div&gt;&lt;div align="justify"&gt;&lt;span style="font-family: arial;"&gt;The following diagram is a view of the back of the Backplane. Attach one Mounting Bracket to the left and right sides of the Backplane as shown below.&lt;br /&gt;&lt;/span&gt;&lt;/div&gt;&lt;div align="justify"&gt;&lt;span style="font-family: arial;"&gt;&lt;/span&gt;&lt;/div&gt;&lt;div align="center"&gt;&lt;a href="http://1.bp.blogspot.com/__O36vLCsD3k/R9eF01dQuHI/AAAAAAAAALE/rErz3f7Z7G0/s1600-h/Clip_19.jpg"&gt;&lt;span style="font-family: arial;"&gt;&lt;img alt="" border="0" id="BLOGGER_PHOTO_ID_5176753439435176050" src="http://1.bp.blogspot.com/__O36vLCsD3k/R9eF01dQuHI/AAAAAAAAALE/rErz3f7Z7G0/s400/Clip_19.jpg" /&gt;&lt;/span&gt;&lt;/a&gt;&lt;/div&gt;&lt;div align="center"&gt;&lt;/div&gt;&lt;div align="justify"&gt;&lt;span style="font-family: arial;"&gt;&lt;/span&gt;&lt;/div&gt;&lt;div align="justify"&gt;&lt;span style="font-family: arial;"&gt;M&lt;/span&gt;&lt;span style="font-family: arial;"&gt;ount the Backplane to the DIN Rail so that the claws on the Mounting Brackets fit into the upper portion of the DIN Rail as shown below.&lt;br /&gt;&lt;/span&gt;&lt;/div&gt;&lt;div align="center"&gt;&lt;a href="http://4.bp.blogspot.com/__O36vLCsD3k/R9eFqldQuGI/AAAAAAAAAK8/3cRYXDzXO9k/s1600-h/Clip_18.jpg"&gt;&lt;span style="font-family: arial;"&gt;&lt;img alt="" border="0" id="BLOGGER_PHOTO_ID_5176753263341516898" src="http://4.bp.blogspot.com/__O36vLCsD3k/R9eFqldQuGI/AAAAAAAAAK8/3cRYXDzXO9k/s400/Clip_18.jpg" /&gt;&lt;/span&gt;&lt;/a&gt;&lt;/div&gt;&lt;div align="center"&gt;&lt;/div&gt;&lt;div align="justify"&gt;&lt;span style="font-family: arial;"&gt;&lt;/span&gt;&lt;/div&gt;&lt;div align="justify"&gt;&lt;span style="font-family: arial;"&gt;Loosen the screws attaching the Mounting Brackets to the Backplane. Slide the Backplane upward as shown below so that the Mounting Bracket and Backplane clamp securely onto the DIN Rail. Tighten the screws.&lt;br /&gt;&lt;/span&gt;&lt;/div&gt;&lt;div align="center"&gt;&lt;a href="http://4.bp.blogspot.com/__O36vLCsD3k/R9eFeldQuFI/AAAAAAAAAK0/SwTfeycb16g/s1600-h/Clip_17.jpg"&gt;&lt;span style="font-family: arial;"&gt;&lt;img alt="" border="0" id="BLOGGER_PHOTO_ID_5176753057183086674" src="http://4.bp.blogspot.com/__O36vLCsD3k/R9eFeldQuFI/AAAAAAAAAK0/SwTfeycb16g/s400/Clip_17.jpg" /&gt;&lt;/span&gt;&lt;/a&gt;&lt;span style="font-family: arial;"&gt;&lt;br /&gt;&lt;/span&gt;&lt;/div&gt;&lt;span style="font-family: arial;"&gt;&lt;/span&gt;&lt;br /&gt;&lt;span style="font-family: Arial;"&gt;&lt;/span&gt;&lt;br /&gt;&lt;div align="justify"&gt;&lt;span style="font-family: arial;"&gt;&lt;br /&gt;&lt;b&gt;3. Installing the Expansion Unit or Expansion I/O Unit&lt;br /&gt;&lt;/b&gt;The Expansion Unit or Expansion I/O Unit are usually attached when amount of I/O devices to be controlled increase its amount over than capacities of the existing I/O Unit or attached when needed to a special need like temperature sensor. The following shown the example of Expansion Units.&lt;br /&gt;&lt;/span&gt;&lt;/div&gt;&lt;div align="center"&gt;&lt;a href="http://1.bp.blogspot.com/__O36vLCsD3k/R9eEU1dQuEI/AAAAAAAAAKs/PloaqR4NIYw/s1600-h/Clip_16.jpg"&gt;&lt;span style="font-family: arial;"&gt;&lt;img alt="" border="0" id="BLOGGER_PHOTO_ID_5176751790167734338" src="http://1.bp.blogspot.com/__O36vLCsD3k/R9eEU1dQuEI/AAAAAAAAAKs/PloaqR4NIYw/s400/Clip_16.jpg" /&gt;&lt;/span&gt;&lt;/a&gt;&lt;/div&gt;&lt;div align="center"&gt;&lt;span style="font-family: arial;"&gt;Expansion Unit of the small PLC&lt;/span&gt;&lt;/div&gt;&lt;span style="font-family: arial;"&gt;&lt;div align="center"&gt;&lt;br /&gt;&lt;/div&gt;&lt;/span&gt;&lt;br /&gt;&lt;a href="http://2.bp.blogspot.com/__O36vLCsD3k/R9eEOFdQuDI/AAAAAAAAAKk/S6X6VmQYc24/s1600-h/Clip_15.jpg"&gt;&lt;span style="font-family: arial;"&gt;&lt;img alt="" border="0" id="BLOGGER_PHOTO_ID_5176751674203617330" src="http://2.bp.blogspot.com/__O36vLCsD3k/R9eEOFdQuDI/AAAAAAAAAKk/S6X6VmQYc24/s400/Clip_15.jpg" /&gt;&lt;/span&gt;&lt;/a&gt;&lt;span style="font-family: arial;"&gt; &lt;/span&gt;&lt;br /&gt;&lt;div align="center"&gt;&lt;span style="font-family: arial;"&gt;Expansion Unit of the big PLC&lt;/span&gt;&lt;/div&gt;&lt;span style="font-family: arial;"&gt;&lt;br /&gt;&lt;/span&gt;&lt;span style="font-family: Arial;"&gt;&lt;/span&gt;&lt;br /&gt;&lt;div align="justify"&gt;&lt;span style="font-family: arial;"&gt;For the small PLC use the following procedure when connecting an Expansion Unit or Expansion I/O Unit;Remove the cover from the CPU Unit’s or the Expansion I/O Unit’s expansion connector. Use a flat-blade screwdriver to remove the cover from the Expansion I/O Connector.&lt;br /&gt;&lt;/span&gt;&lt;/div&gt;&lt;div align="center"&gt;&lt;a href="http://3.bp.blogspot.com/__O36vLCsD3k/R9eD-VdQuCI/AAAAAAAAAKc/JVWipIKaMkI/s1600-h/Clip_13.jpg"&gt;&lt;span style="font-family: arial;"&gt;&lt;img alt="" border="0" id="BLOGGER_PHOTO_ID_5176751403620677666" src="http://3.bp.blogspot.com/__O36vLCsD3k/R9eD-VdQuCI/AAAAAAAAAKc/JVWipIKaMkI/s400/Clip_13.jpg" /&gt;&lt;/span&gt;&lt;/a&gt;&lt;/div&gt;&lt;div align="justify"&gt;&lt;span style="font-family: arial;"&gt;&lt;br /&gt;&lt;/span&gt;&lt;span style="font-family: arial;"&gt;Insert the Expansion I/O Unit’s connecting cable into the CPU Unit’s or the Expansion I/O Unit’s expansion connector.&lt;br /&gt;&lt;/span&gt;&lt;/div&gt;&lt;div align="center"&gt;&lt;a href="http://2.bp.blogspot.com/__O36vLCsD3k/R9eDzFdQuBI/AAAAAAAAAKU/Ar2g76cx7Bg/s1600-h/Clip_12.jpg"&gt;&lt;span style="font-family: arial;"&gt;&lt;img alt="" border="0" id="BLOGGER_PHOTO_ID_5176751210347149330" src="http://2.bp.blogspot.com/__O36vLCsD3k/R9eDzFdQuBI/AAAAAAAAAKU/Ar2g76cx7Bg/s400/Clip_12.jpg" /&gt;&lt;/span&gt;&lt;/a&gt;&lt;/div&gt;&lt;div align="justify"&gt;&lt;span style="font-family: arial;"&gt;&lt;/span&gt;&lt;br /&gt;&lt;span style="font-family: arial;"&gt;Replace the cover on the CPU Unit’s or the Expansion I/O Unit’s expansion connector.&lt;br /&gt;&lt;/span&gt;&lt;/div&gt;&lt;div align="center"&gt;&lt;a href="http://2.bp.blogspot.com/__O36vLCsD3k/R9eDpFdQuAI/AAAAAAAAAKM/pK1qe-933-8/s1600-h/Clip_11.jpg"&gt;&lt;span style="font-family: arial;"&gt;&lt;img alt="" border="0" id="BLOGGER_PHOTO_ID_5176751038548457474" src="http://2.bp.blogspot.com/__O36vLCsD3k/R9eDpFdQuAI/AAAAAAAAAKM/pK1qe-933-8/s400/Clip_11.jpg" /&gt;&lt;/span&gt;&lt;/a&gt;&lt;/div&gt;&lt;span style="font-family: arial;"&gt;&lt;div align="justify"&gt;&lt;br /&gt;&lt;/div&gt;&lt;/span&gt;&lt;br /&gt;&lt;span style="font-family: arial;"&gt;For the big PLC use the following picture when connecting an Expansion Unit or Expansion I/O Unit;&lt;br /&gt;&lt;/span&gt;&lt;br /&gt;&lt;div align="center"&gt;&lt;a href="http://3.bp.blogspot.com/__O36vLCsD3k/R9eDfVdQt_I/AAAAAAAAAKE/TRCUFYt5MH8/s1600-h/Clip_10.jpg"&gt;&lt;span style="font-family: arial;"&gt;&lt;img alt="" border="0" id="BLOGGER_PHOTO_ID_5176750871044732914" src="http://3.bp.blogspot.com/__O36vLCsD3k/R9eDfVdQt_I/AAAAAAAAAKE/TRCUFYt5MH8/s400/Clip_10.jpg" /&gt;&lt;/span&gt;&lt;/a&gt;&lt;/div&gt;&lt;div align="justify"&gt;&lt;span style="font-family: arial;"&gt;&lt;/span&gt;&lt;/div&gt;&lt;span style="font-family: arial;"&gt;&lt;div align="justify"&gt;&lt;br /&gt;&lt;/div&gt;&lt;/span&gt;&lt;span style="font-family: arial;"&gt;&lt;b&gt;&lt;/b&gt;&lt;/span&gt;&lt;br /&gt;&lt;div align="justify"&gt;&lt;span style="font-family: arial;"&gt;&lt;b&gt;4. Installing I/O devices&lt;/b&gt;&lt;br /&gt;I/O devices are attached at the place have been determined in the work plan and wiring diagram. For switches are usually attached at the panel while the sensor, selenoid and motor is usually placed at the machine to be controlled.&lt;/span&gt;&lt;/div&gt;&lt;span style="font-family: arial;"&gt;&lt;div align="justify"&gt;&lt;br /&gt;&lt;br /&gt;&lt;b&gt;5. Wiring and connections&lt;/b&gt;&lt;br /&gt;&lt;i&gt;Duct Work&lt;/i&gt;&lt;br /&gt;Hanging Ducts If power cables carrying more than 10 A 400 V, or 20 A 220 V must be run alongside the I/O wiring (that is, in parallel with it), at least 300 mm must be left between the power cables and the I/O wiring as shown below.&lt;/div&gt;&lt;/span&gt;&lt;br /&gt;&lt;div align="center"&gt;&lt;a href="http://1.bp.blogspot.com/__O36vLCsD3k/R9eCo1dQt-I/AAAAAAAAAJ8/oFynwwTRs7A/s1600-h/Clip_9.jpg"&gt;&lt;span style="font-family: arial;"&gt;&lt;img alt="" border="0" id="BLOGGER_PHOTO_ID_5176749934741862370" src="http://1.bp.blogspot.com/__O36vLCsD3k/R9eCo1dQt-I/AAAAAAAAAJ8/oFynwwTRs7A/s400/Clip_9.jpg" /&gt;&lt;/span&gt;&lt;/a&gt;&lt;/div&gt;&lt;div align="justify"&gt;&lt;span style="font-family: arial;"&gt;&lt;/span&gt;&lt;br /&gt;&lt;span style="font-family: arial;"&gt;Floor Ducts If the I/O wiring and power cables must be placed in the same duct (for example, where they are connected to the equipment), they must be shielded from each other using grounded metal plates.&lt;br /&gt;&lt;/span&gt;&lt;/div&gt;&lt;div align="center"&gt;&lt;a href="http://1.bp.blogspot.com/__O36vLCsD3k/R9eCd1dQt9I/AAAAAAAAAJ0/vVDvusdkITw/s1600-h/Clip_8.jpg"&gt;&lt;span style="font-family: arial;"&gt;&lt;img alt="" border="0" id="BLOGGER_PHOTO_ID_5176749745763301330" src="http://1.bp.blogspot.com/__O36vLCsD3k/R9eCd1dQt9I/AAAAAAAAAJ0/vVDvusdkITw/s400/Clip_8.jpg" /&gt;&lt;/span&gt;&lt;/a&gt;&lt;/div&gt;&lt;div align="justify"&gt;&lt;span style="font-family: arial;"&gt;&lt;br /&gt;&lt;/span&gt;&lt;br /&gt;&lt;span style="font-family: arial;"&gt;Conduits if Separating the PLC I/O lines, power and control lines, and power cables, as shown in the following diagram.&lt;br /&gt;&lt;/span&gt;&lt;/div&gt;&lt;div align="center"&gt;&lt;a href="http://4.bp.blogspot.com/__O36vLCsD3k/R9eCRldQt8I/AAAAAAAAAJs/NWkOlmDPtKc/s1600-h/Clip_7.jpg"&gt;&lt;span style="font-family: arial;"&gt;&lt;img alt="" border="0" id="BLOGGER_PHOTO_ID_5176749535309903810" src="http://4.bp.blogspot.com/__O36vLCsD3k/R9eCRldQt8I/AAAAAAAAAJs/NWkOlmDPtKc/s400/Clip_7.jpg" /&gt;&lt;/span&gt;&lt;/a&gt;&lt;/div&gt;&lt;div align="justify"&gt;&lt;span style="font-family: arial;"&gt;&lt;/span&gt;&lt;br /&gt;&lt;span style="font-family: arial;"&gt;&lt;br /&gt;&lt;i&gt;I/O connections&lt;/i&gt;&lt;br /&gt;Connect the I/O Devices to the I/O Units. Use 1.25-mm2 cables or larger The terminals have screws with 3.5-mm diameter heads and self-raising pressure plates. Connect the lead wires to the terminals as shown below. Tighten the screws with a torque of 0.8 N _ m.&lt;/span&gt;&lt;/div&gt;&lt;div align="center"&gt;&lt;a href="http://3.bp.blogspot.com/__O36vLCsD3k/R9eBiVdQt7I/AAAAAAAAAJk/joQyZtYwFHg/s1600-h/Clip_6.jpg"&gt;&lt;span style="font-family: arial;"&gt;&lt;img alt="" border="0" id="BLOGGER_PHOTO_ID_5176748723561084850" src="http://3.bp.blogspot.com/__O36vLCsD3k/R9eBiVdQt7I/AAAAAAAAAJk/joQyZtYwFHg/s400/Clip_6.jpg" /&gt;&lt;/span&gt;&lt;/a&gt;&lt;/div&gt;&lt;div align="center"&gt;&lt;/div&gt;&lt;div align="justify"&gt;&lt;span style="font-family: arial;"&gt;If you wish to attach solderless type terminals to the ends of the lead wires, use terminals having the dimensions shown below.&lt;br /&gt;&lt;/span&gt;&lt;/div&gt;&lt;div align="center"&gt;&lt;img alt="" border="0" id="BLOGGER_PHOTO_ID_5176747813028018082" src="http://3.bp.blogspot.com/__O36vLCsD3k/R9eAtVdQt6I/AAAAAAAAAJc/_KSken8hB8g/s400/Clip_5.jpg" /&gt;&lt;/div&gt;&lt;div align="center"&gt;&lt;/div&gt;&lt;div align="justify"&gt;&lt;span style="font-family: arial;"&gt;The following diagrams show the input configurations. This input configuration depend on specification of the Input Unit will be used. See the specification before install.&lt;br /&gt;&lt;/span&gt;&lt;/div&gt;&lt;div align="center"&gt;&lt;a href="http://1.bp.blogspot.com/__O36vLCsD3k/R9eAE1dQt5I/AAAAAAAAAJU/TIkZkO8tp4w/s1600-h/Clip_4.jpg"&gt;&lt;span style="font-family: arial;"&gt;&lt;img alt="" border="0" id="BLOGGER_PHOTO_ID_5176747117243316114" src="http://1.bp.blogspot.com/__O36vLCsD3k/R9eAE1dQt5I/AAAAAAAAAJU/TIkZkO8tp4w/s400/Clip_4.jpg" /&gt;&lt;/span&gt;&lt;/a&gt;&lt;/div&gt;&lt;div align="center"&gt;&lt;span style="font-family: arial;"&gt;&lt;/span&gt;&lt;/div&gt;&lt;div align="justify"&gt;&lt;span style="font-family: arial;"&gt;The following diagrams show the input configurations. This output configuration depend on specification of the Output Unit will be used. See the specification before install.&lt;br /&gt;&lt;/span&gt;&lt;/div&gt;&lt;div align="center"&gt;&lt;a href="http://1.bp.blogspot.com/__O36vLCsD3k/R9d_o1dQt4I/AAAAAAAAAJM/q6MpIqItmvs/s1600-h/Clip_3.jpg"&gt;&lt;span style="font-family: arial;"&gt;&lt;img alt="" border="0" id="BLOGGER_PHOTO_ID_5176746636206978946" src="http://1.bp.blogspot.com/__O36vLCsD3k/R9d_o1dQt4I/AAAAAAAAAJM/q6MpIqItmvs/s400/Clip_3.jpg" /&gt;&lt;/span&gt;&lt;/a&gt;&lt;/div&gt;&lt;span style="font-family: arial;"&gt;&lt;div align="justify"&gt;&lt;br /&gt;&lt;/div&gt;&lt;i&gt;&lt;/i&gt;&lt;div align="justify"&gt;&lt;i&gt;Power supply wiring&lt;/i&gt;&lt;br /&gt;The following example show the proper way to connect the power source to the PLC. Use 1.25-mm2 cables or larger. The terminal blocks have screws with 3.5-mm diameter heads and self-raising pressure plates. For connecting to the terminal blocks, use round crimp terminals for 3.5-mm diameter heads. Directly connecting stranded wires to the terminal blocks may cause a short-circuit.&lt;/div&gt;&lt;/span&gt;&lt;br /&gt;&lt;div align="justify"&gt;&lt;/div&gt;&lt;div align="center"&gt;&lt;a href="http://1.bp.blogspot.com/__O36vLCsD3k/R9d8A1dQtuI/AAAAAAAAAH8/ako4rYJhItM/s1600-h/Clip_2.jpg"&gt;&lt;span style="font-family: arial;"&gt;&lt;img alt="" border="0" id="BLOGGER_PHOTO_ID_5176742650477328098" src="http://1.bp.blogspot.com/__O36vLCsD3k/R9d8A1dQtuI/AAAAAAAAAH8/ako4rYJhItM/s400/Clip_2.jpg" /&gt;&lt;/span&gt;&lt;/a&gt;&lt;/div&gt;&lt;div align="center"&gt;&lt;span style="font-family: arial;"&gt;Power supply wiring on the Omron PLC&lt;/span&gt;&lt;/div&gt;&lt;div align="justify"&gt;&lt;span style="font-family: arial;"&gt;&lt;br /&gt;&lt;/span&gt;&lt;/div&gt;&lt;span style="font-family: arial;"&gt;&lt;br /&gt;&lt;br /&gt;&lt;i&gt;&lt;/i&gt;&lt;div align="justify"&gt;&lt;i&gt;Grounding&lt;/i&gt;&lt;br /&gt;This PLC has sufficient protection against noise, so it can be used without grounding except for special much noise. However, when grounding it should be done conforming to below items. Ground the PLC as independently as possible. Class 3 grounding should be used (grounding resistance 100Ω or less). When independent grounding is impossible, use the joint grounding method as shown in the figure below (B). Use thicker grounding wire. Grounding point should be as near as possible to the PLC to minimize the distance of grounding cable. &lt;/div&gt;&lt;div align="justify"&gt;See the picture below;&lt;/div&gt;&lt;/span&gt;&lt;br /&gt;&lt;div align="center"&gt;&lt;a href="http://2.bp.blogspot.com/__O36vLCsD3k/R9d7oFdQttI/AAAAAAAAAH0/rj8rNLP59d8/s1600-h/Clip.jpg"&gt;&lt;span style="font-family: arial;"&gt;&lt;img alt="" border="0" id="BLOGGER_PHOTO_ID_5176742225275565778" src="http://2.bp.blogspot.com/__O36vLCsD3k/R9d7oFdQttI/AAAAAAAAAH0/rj8rNLP59d8/s400/Clip.jpg" /&gt;&lt;/span&gt;&lt;/a&gt;&lt;/div&gt;&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/5812867464294190346-403639704887239903?l=plc-installation.blogspot.com' alt='' /&gt;&lt;/div&gt;</description><link>http://plc-installation.blogspot.com/2008/03/power-supply-wiringthe-following.html</link><author>noreply@blogger.com (AGUNG)</author><media:thumbnail xmlns:media='http://search.yahoo.com/mrss/' url='http://4.bp.blogspot.com/__O36vLCsD3k/R9fKVldQuWI/AAAAAAAAAM8/h8n0bXXEM4U/s72-c/Clip_32.jpg' height='72' width='72'/></item><item><guid isPermaLink='false'>tag:blogger.com,1999:blog-5812867464294190346.post-6191861593844008920</guid><pubDate>Tue, 11 Mar 2008 01:57:00 +0000</pubDate><atom:updated>2010-11-07T22:50:37.830+08:00</atom:updated><title>Matters that must be known before installing the PLC</title><description>&lt;div align="justify"&gt;&lt;span style="font-family: arial;"&gt;&lt;b&gt;Safety Procedure&lt;br /&gt;&lt;/b&gt;Safety Procedure is a prevention action so that is not happened the accident at the time of work excecution that may be happened to the worker or other people, machine, equipment and environmental in any time and any where.&lt;/span&gt;&lt;/div&gt;&lt;span style="font-family: arial;"&gt;&lt;div align="justify"&gt;&lt;br /&gt;The safety equipment for example:&lt;/div&gt;&lt;ul&gt;&lt;li&gt;Wear&lt;/li&gt;&lt;li&gt;Safety shoes&lt;img alt="" border="0" height="1" src="http://www.assoc-amazon.com/e/ir?t=pi0fa-20&amp;amp;l=btl&amp;amp;camp=213689&amp;amp;creative=392969&amp;amp;o=1&amp;amp;a=B000XF38YW" style="border: medium none ! important; margin: 0px ! important; padding: 0px ! important;" width="1" /&gt;&lt;/li&gt;&lt;li&gt;Helmet&lt;img alt="" border="0" height="1" src="http://www.assoc-amazon.com/e/ir?t=pi0fa-20&amp;amp;l=btl&amp;amp;camp=213689&amp;amp;creative=392969&amp;amp;o=1&amp;amp;a=B003V89Y1O" style="border: medium none ! important; margin: 0px ! important; padding: 0px ! important;" width="1" /&gt;&lt;/li&gt;&lt;li&gt;Gloves&lt;img alt="" border="0" height="1" src="http://www.assoc-amazon.com/e/ir?t=pi0fa-20&amp;amp;l=btl&amp;amp;camp=213689&amp;amp;creative=392969&amp;amp;o=1&amp;amp;a=B000FPDPCK" style="border: medium none ! important; margin: 0px ! important; padding: 0px ! important;" width="1" /&gt;&lt;/li&gt;&lt;li&gt;Safety glasses&lt;img alt="" border="0" height="1" src="http://www.assoc-amazon.com/e/ir?t=pi0fa-20&amp;amp;l=btl&amp;amp;camp=213689&amp;amp;creative=392969&amp;amp;o=1&amp;amp;a=B000RKQ1NI" style="border: medium none ! important; margin: 0px ! important; padding: 0px ! important;" width="1" /&gt;&lt;/li&gt;&lt;li&gt;Masker, etc&lt;br /&gt;&lt;/li&gt;&lt;/ul&gt;Prevention of the happening of accident in the work place must pay attention some factors for example :&lt;br /&gt;&lt;ul&gt;&lt;li&gt;&lt;div align="justify"&gt;Ascertaining equipments in good condition&lt;/div&gt;&lt;/li&gt;&lt;li&gt;&lt;div align="justify"&gt;Ascertaining wear in good condition&lt;/div&gt;&lt;/li&gt;&lt;li&gt;&lt;div align="justify"&gt;Must discipline in using the equipment&lt;/div&gt;&lt;/li&gt;&lt;li&gt;&lt;div align="justify"&gt;Must attentive and concentration at the work&lt;/div&gt;&lt;/li&gt;&lt;li&gt;&lt;div align="justify"&gt;Ascertaining has comprehended the way of operation of the machine or equipment&lt;/div&gt;&lt;/li&gt;&lt;li&gt;&lt;div align="justify"&gt;Ascertaining body condition before working in good health&lt;/div&gt;&lt;/li&gt;&lt;/ul&gt;&lt;div align="justify"&gt;&lt;br /&gt;&lt;/div&gt;&lt;b&gt;&lt;/b&gt;&lt;div align="justify"&gt;&lt;b&gt;Equipments and materials of installation of the PLC are attached as according to specification of devices, standard and conditions&lt;br /&gt;&lt;/b&gt;The PLC (Programmable Logic Controller&lt;img alt="" border="0" height="1" src="http://www.assoc-amazon.com/e/ir?t=pi0fa-20&amp;amp;l=btl&amp;amp;camp=213689&amp;amp;creative=392969&amp;amp;o=1&amp;amp;a=1605250066" style="border: medium none ! important; margin: 0px ! important; padding: 0px ! important;" width="1" /&gt;) is an automatic controller based on microcontroller and could be programmed. The PLC is used to replace the conventional controller or the controller based on relay. Each brand of the PLC have the different specification but principally, its installation procedure much the same because hardwares of the PLC are only consist of several components; such as Power Supply Unit, CPU Unit, Memory Unit and I/O Unit. Installation of the PLC must as according to installation guide because wrong installation can result damage at the PLC. &lt;/div&gt;&lt;div align="justify"&gt;&lt;/div&gt;&lt;/span&gt;&lt;b&gt;&lt;span style="font-family: arial;"&gt;&lt;/span&gt;&lt;/b&gt;&lt;br /&gt;&lt;div align="justify"&gt;&lt;b&gt;&lt;span style="font-family: arial;"&gt;&lt;/span&gt;&lt;/b&gt;&lt;/div&gt;&lt;div align="justify"&gt;&lt;b&gt;&lt;span style="font-family: arial;"&gt;&lt;/span&gt;&lt;/b&gt;&lt;/div&gt;&lt;div align="justify"&gt;&lt;b&gt;&lt;span style="font-family: arial;"&gt;Hardwares of the PLC&lt;br /&gt;&lt;/span&gt;&lt;/b&gt;&lt;span style="font-family: arial;"&gt;Hardwares of the PLC are only consist of several components; such as Power Supply Unit, CPU Unit, Memory Unit and I/O Unit. At the small PLC; Power Supply, CPU, Memory and I/O stay in the same Unit but at the big PLC; Power Supply, CPU, Memory and I/O in the separate Unit.&lt;/span&gt;&lt;/div&gt;&lt;div align="justify"&gt;&lt;span style="font-family: arial;"&gt;See the picture below;&lt;/span&gt;&lt;/div&gt;&lt;div align="center"&gt;&lt;a href="http://1.bp.blogspot.com/__O36vLCsD3k/R9YHGFdQtNI/AAAAAAAAACE/zU9uGmekPLM/s1600-h/Clip_10.jpg"&gt;&lt;span style="font-family: arial;"&gt;&lt;img alt="" border="0" height="268" id="BLOGGER_PHOTO_ID_5176332622834480338" src="http://1.bp.blogspot.com/__O36vLCsD3k/R9YHGFdQtNI/AAAAAAAAACE/zU9uGmekPLM/s400/Clip_10.jpg" style="height: 254px; width: 363px;" width="363" /&gt;&lt;/span&gt;&lt;/a&gt;&lt;/div&gt;&lt;div align="center"&gt;&lt;span style="font-family: arial;"&gt;Block diagram of PLC&lt;/span&gt;&lt;/div&gt;&lt;br /&gt;&lt;br /&gt;&lt;div align="center"&gt;&lt;a href="http://4.bp.blogspot.com/__O36vLCsD3k/R9YGz1dQtMI/AAAAAAAAAB8/oIE6czFUNLM/s1600-h/Clip_9.jpg"&gt;&lt;span style="font-family: arial;"&gt;&lt;img alt="" border="0" id="BLOGGER_PHOTO_ID_5176332309301867714" src="http://4.bp.blogspot.com/__O36vLCsD3k/R9YGz1dQtMI/AAAAAAAAAB8/oIE6czFUNLM/s400/Clip_9.jpg" /&gt;&lt;/span&gt;&lt;/a&gt;&lt;/div&gt;&lt;div align="center"&gt;&lt;span style="font-family: arial;"&gt;The small Omron PLC&lt;/span&gt;&lt;/div&gt;&lt;span style="font-family: arial;"&gt;&lt;div align="left"&gt;&lt;br /&gt;&lt;br /&gt;&lt;/div&gt;&lt;/span&gt;&lt;br /&gt;&lt;div align="center"&gt;&lt;a href="http://1.bp.blogspot.com/__O36vLCsD3k/R9YGmFdQtLI/AAAAAAAAAB0/6uDEji2iEpI/s1600-h/Clip_8.jpg"&gt;&lt;span style="font-family: arial;"&gt;&lt;img alt="" border="0" id="BLOGGER_PHOTO_ID_5176332073078666418" src="http://1.bp.blogspot.com/__O36vLCsD3k/R9YGmFdQtLI/AAAAAAAAAB0/6uDEji2iEpI/s400/Clip_8.jpg" /&gt;&lt;/span&gt;&lt;/a&gt;&lt;/div&gt;&lt;div align="center"&gt;&lt;span style="font-family: arial;"&gt;The big Omron PLC&lt;/span&gt;&lt;/div&gt;&lt;div align="center"&gt;&lt;span style="font-family: Arial;"&gt;&lt;/span&gt;&lt;/div&gt;&lt;div align="center"&gt;&lt;span style="font-family: Arial;"&gt;&lt;/span&gt;&lt;/div&gt;&lt;div align="center"&gt;&lt;span style="font-family: arial;"&gt;&lt;br /&gt;&lt;/span&gt;&lt;a href="http://2.bp.blogspot.com/__O36vLCsD3k/R9YGHVdQtKI/AAAAAAAAABs/XwYuLcHawTQ/s1600-h/Clip_7.jpg"&gt;&lt;span style="font-family: arial;"&gt;&lt;img alt="" border="0" id="BLOGGER_PHOTO_ID_5176331544797688994" src="http://2.bp.blogspot.com/__O36vLCsD3k/R9YGHVdQtKI/AAAAAAAAABs/XwYuLcHawTQ/s400/Clip_7.jpg" /&gt;&lt;/span&gt;&lt;/a&gt;&lt;/div&gt;&lt;div align="center"&gt;&lt;span style="font-family: arial;"&gt;The small LG PLC&lt;br /&gt;&lt;br /&gt;&lt;br /&gt;&lt;/span&gt;&lt;/div&gt;&lt;div align="center"&gt;&lt;a href="http://3.bp.blogspot.com/__O36vLCsD3k/R9YFIldQtJI/AAAAAAAAABk/D9lfAcORk0I/s1600-h/Clip_6.jpg"&gt;&lt;span style="font-family: arial;"&gt;&lt;img alt="" border="0" id="BLOGGER_PHOTO_ID_5176330466760897682" src="http://3.bp.blogspot.com/__O36vLCsD3k/R9YFIldQtJI/AAAAAAAAABk/D9lfAcORk0I/s400/Clip_6.jpg" /&gt;&lt;/span&gt;&lt;/a&gt;&lt;/div&gt;&lt;div align="center"&gt;&lt;span style="font-family: arial;"&gt;The big LG PLC&lt;br /&gt;&lt;/span&gt;&lt;/div&gt;&lt;div align="justify"&gt;&lt;span style="font-family: arial;"&gt;&lt;b&gt;&lt;/b&gt;&lt;/span&gt;&lt;/div&gt;&lt;div align="justify"&gt;&lt;span style="font-family: arial;"&gt;&lt;i&gt;&lt;/i&gt;&lt;/span&gt;&lt;/div&gt;&lt;div align="justify"&gt;&lt;span style="font-family: arial;"&gt;&lt;br /&gt;&lt;i&gt;Power Supply&lt;/i&gt;&lt;br /&gt;The Power Supply is used to give power to all the parts. The most PLC works with power 24 VDC or 220 VAC. The big PLC has the separate power supply and the small PLC has power supply which is one. The Power Supply is also provided by the battery back up, when happened the failure of power, automatically battery will replace the power supply to supply the CPU, so that the program of memory user do not lose.&lt;/span&gt;&lt;/div&gt;&lt;br /&gt;&lt;div align="justify"&gt;&lt;span style="font-family: arial;"&gt;&lt;i&gt;CPU Unit (Central Processing Unit) &lt;/i&gt;&lt;br /&gt;Without seeing to type of PLC ( small, medium, big) prosesor and memory always in the same unit. This unit is referred as the CPU. The CPU is the brain of a PLC. The CPU is a 8 bit, 16 bit or 32 bit microcontroller. The CPU has function to handle communications with the eksternal apparatus, interconnectivity between the parts of PLC, executes the program, managements the memory, observing or perceiving the input signal and gives the output signal ( as according to the program or process run). The CPU is also provided by the indicator lamp as indicator of the happening of mistake and damage. &lt;/span&gt;&lt;/div&gt;&lt;div align="justify"&gt;&lt;span style="font-family: arial;"&gt;See the picture below;&lt;br /&gt;&lt;/span&gt;&lt;/div&gt;&lt;div align="center"&gt;&lt;a href="http://1.bp.blogspot.com/__O36vLCsD3k/R9YElFdQtII/AAAAAAAAABc/EyUO8H97_7Y/s1600-h/Clip_5.jpg"&gt;&lt;span style="font-family: arial;"&gt;&lt;img alt="" border="0" id="BLOGGER_PHOTO_ID_5176329856875541634" src="http://1.bp.blogspot.com/__O36vLCsD3k/R9YElFdQtII/AAAAAAAAABc/EyUO8H97_7Y/s400/Clip_5.jpg" /&gt;&lt;/span&gt;&lt;/a&gt;&lt;/div&gt;&lt;div align="center"&gt;The CPU of Omron PLC&lt;/div&gt;&lt;div align="center"&gt;&lt;span style="font-family: arial;"&gt;&lt;/span&gt;&lt;/div&gt;&lt;br /&gt;&lt;div align="center"&gt;&lt;a href="http://2.bp.blogspot.com/__O36vLCsD3k/R9YESVdQtHI/AAAAAAAAABU/JZ_hLr5SaQQ/s1600-h/Clip_4.jpg"&gt;&lt;span style="font-family: arial;"&gt;&lt;img alt="" border="0" id="BLOGGER_PHOTO_ID_5176329534752994418" src="http://2.bp.blogspot.com/__O36vLCsD3k/R9YESVdQtHI/AAAAAAAAABU/JZ_hLr5SaQQ/s400/Clip_4.jpg" /&gt;&lt;/span&gt;&lt;/a&gt;&lt;/div&gt;&lt;div align="center"&gt;&lt;span style="font-family: arial;"&gt;CPU Indicators&lt;br /&gt;&lt;br /&gt;&lt;br /&gt;&lt;/span&gt;&lt;/div&gt;&lt;br /&gt;&lt;div align="justify"&gt;&lt;span style="font-family: arial;"&gt;&lt;i&gt;&lt;/i&gt;&lt;/span&gt;&lt;/div&gt;&lt;div align="justify"&gt;&lt;span style="font-family: arial;"&gt;&lt;i&gt;I/O Unit&lt;br /&gt;&lt;/i&gt;The I/O Unit is the interface unit has function to convert the input signal and output signal so that the CPU can communicate with the external apparatus like the switch, stepping motor, solenoid, sensor, etc. The I/O Unit has two type; Discrete I/O and Analog I/O.&lt;/span&gt;&lt;/div&gt;&lt;div align="justify"&gt;&lt;span style="font-family: arial;"&gt;See the picture below;&lt;br /&gt;&lt;/span&gt;&lt;/div&gt;&lt;div align="center"&gt;&lt;a href="http://3.bp.blogspot.com/__O36vLCsD3k/R9YD3ldQtGI/AAAAAAAAABM/KHUnO7WwirM/s1600-h/Clip_3.jpg"&gt;&lt;span style="font-family: arial;"&gt;&lt;img alt="" border="0" id="BLOGGER_PHOTO_ID_5176329075191493730" src="http://3.bp.blogspot.com/__O36vLCsD3k/R9YD3ldQtGI/AAAAAAAAABM/KHUnO7WwirM/s400/Clip_3.jpg" /&gt;&lt;/span&gt;&lt;/a&gt;&lt;/div&gt;&lt;div align="center"&gt;&lt;span style="font-family: arial;"&gt;The I/O Unit of Omron PLC&lt;br /&gt;&lt;/span&gt;&lt;/div&gt;&lt;span style="font-family: arial;"&gt;&lt;i&gt;&lt;/i&gt;&lt;/span&gt;&lt;br /&gt;&lt;div align="justify"&gt;&lt;span style="font-family: arial;"&gt;&lt;i&gt;Memory Unit&lt;/i&gt;&lt;/span&gt;&lt;br /&gt;&lt;span style="font-family: arial;"&gt;The Memory Unit has function to save the data and program will be used by PLC. This Memory is divisible into two type that is ROM and RAM. ROM contains the data like facility of the logic program, facility to edit the program, facility to monitor the program, facility for the communications, etc. The Data will be save permanently and will not lose though the power supply is off. While RAM contains the data of user program, like ladder diagram, memory data, I/O status, etc. The Data can be writed and read. RAM has the character is not permanent, if the power suplply is off the data will lose. To avoid the mentioned, so the power supply is provided by the battery back up to supply if the especial power supply is off.&lt;/span&gt;&lt;/div&gt;&lt;div align="justify"&gt;&lt;/div&gt;&lt;div align="justify"&gt;&lt;span style="font-family: arial;"&gt;&lt;i&gt;&lt;/i&gt;&lt;/span&gt;&lt;/div&gt;&lt;div align="justify"&gt;&lt;span style="font-family: arial;"&gt;&lt;i&gt;Input Devices&lt;/i&gt;&lt;br /&gt;PLCs can receive input from either automated or manual devices. The PLC could receive data from the user via a pushbutton switch, keyboard, or similar device. Automated input could come from a variety of devices: microswitches, timers, encoders, photosensors, and so on. Some devices, like the Limit Switch shown below, turn ON or OFF when the equipment actually makes contact with it. Other devices, like the Photoelectric Switch and Proximity Switch shown below, use other means, such as light or inductance, in order to get information about the equipment being monitored. See the picture below;&lt;br /&gt;&lt;/span&gt;&lt;/div&gt;&lt;div align="center"&gt;&lt;a href="http://2.bp.blogspot.com/__O36vLCsD3k/R9YDdVdQtFI/AAAAAAAAABE/tFgGHNvfPI8/s1600-h/Clip_2.jpg"&gt;&lt;span style="font-family: arial;"&gt;&lt;img alt="" border="0" id="BLOGGER_PHOTO_ID_5176328624219927634" src="http://2.bp.blogspot.com/__O36vLCsD3k/R9YDdVdQtFI/AAAAAAAAABE/tFgGHNvfPI8/s400/Clip_2.jpg" /&gt;&lt;/span&gt;&lt;/a&gt;&lt;/div&gt;&lt;br /&gt;&lt;span style="font-family: arial;"&gt;&lt;div align="justify"&gt;&lt;br /&gt;&lt;i&gt;Output Devices&lt;/i&gt;&lt;br /&gt;A PLC can output to a myriad of devices for use in automated control. Almost anything that you can think of could be controlled (perhaps indirectly) by a PLC. Some of the most common devices are motors, Solenoids, Servomotors, Stepping Motors, valves, switches, indicator lights, buzzers, and alarms. Some of these output devices; such as the motors, Solenoids, Servomotors, Stepping Motors, and valves; affect the controlled system directly. Others; such as the indicator lights, buzzers, and alarms; provide output to notify personnel.&lt;/div&gt;&lt;/span&gt;&lt;br /&gt;&lt;div align="center"&gt;&lt;a href="http://3.bp.blogspot.com/__O36vLCsD3k/R9YDFldQtEI/AAAAAAAAAA8/93_4ricSIXg/s1600-h/Clip.jpg"&gt;&lt;span style="font-family: arial;"&gt;&lt;img alt="" border="0" id="BLOGGER_PHOTO_ID_5176328216198034498" src="http://3.bp.blogspot.com/__O36vLCsD3k/R9YDFldQtEI/AAAAAAAAAA8/93_4ricSIXg/s400/Clip.jpg" /&gt;&lt;/span&gt;&lt;/a&gt;&lt;/div&gt;&lt;div align="center"&gt;&lt;/div&gt;&lt;span style="font-family: arial;"&gt;&lt;b&gt;&lt;/b&gt;&lt;/span&gt;&lt;br /&gt;&lt;span style="font-family: arial;"&gt;&lt;b&gt;&lt;/b&gt;&lt;/span&gt;&lt;br /&gt;&lt;span style="font-family: arial;"&gt;&lt;b&gt;&lt;/b&gt;&lt;/span&gt;&lt;br /&gt;&lt;div align="justify"&gt;&lt;br /&gt;&lt;span style="font-family: arial;"&gt;&lt;b&gt;The necessary environmental conditions for installing the PLC&lt;/b&gt;&lt;br /&gt;Do not install the PLC in any of the following locations. Doing so will affect PLC life and may affect operating performance.&lt;/span&gt;&lt;/div&gt;&lt;ul&gt;&lt;li&gt;&lt;div align="justify"&gt;&lt;span style="font-family: arial;"&gt;Locations subject to ambient temperatures lower than 0°C or higher than 55°C &lt;/span&gt;&lt;/div&gt;&lt;/li&gt;&lt;li&gt;&lt;div align="justify"&gt;&lt;span style="font-family: arial;"&gt;Locations subject to drastic temperature changes or condensation &lt;/span&gt;&lt;/div&gt;&lt;/li&gt;&lt;li&gt;&lt;div align="justify"&gt;&lt;span style="font-family: arial;"&gt;Locations subject to ambient humidity lower than 10% or higher than 90% &lt;/span&gt;&lt;/div&gt;&lt;/li&gt;&lt;li&gt;&lt;div align="justify"&gt;&lt;span style="font-family: arial;"&gt;Locations subject to corrosive or flammable gases &lt;/span&gt;&lt;/div&gt;&lt;/li&gt;&lt;li&gt;&lt;div align="justify"&gt;&lt;span style="font-family: arial;"&gt;Locations subject to excessive dust (especially iron dust) or chloride &lt;/span&gt;&lt;/div&gt;&lt;/li&gt;&lt;li&gt;&lt;div align="justify"&gt;&lt;span style="font-family: arial;"&gt;Locations that would subject the CPU to direct shock or vibration &lt;/span&gt;&lt;/div&gt;&lt;/li&gt;&lt;li&gt;&lt;div align="justify"&gt;&lt;span style="font-family: arial;"&gt;Locations that would subject the PC to water, oil, or chemical reagents &lt;/span&gt;&lt;/div&gt;&lt;/li&gt;&lt;li&gt;&lt;div align="justify"&gt;&lt;span style="font-family: arial;"&gt;Locations exposed to direct sunlight&lt;br /&gt;&lt;/span&gt;&lt;/div&gt;&lt;/li&gt;&lt;/ul&gt;&lt;span style="font-family: arial;"&gt;&lt;br /&gt;&lt;/span&gt;&lt;br /&gt;&lt;span style="font-family: arial;"&gt;Take appropriate and sufficient countermeasures when installing systems in the following locations:&lt;/span&gt;&lt;br /&gt;&lt;ul&gt;&lt;li&gt;&lt;div align="justify"&gt;&lt;span style="font-family: arial;"&gt;Locations subject to static electricity or other forms of noise &lt;/span&gt;&lt;/div&gt;&lt;/li&gt;&lt;li&gt;&lt;div align="justify"&gt;&lt;span style="font-family: arial;"&gt;Locations subject to strong electromagnetic fields &lt;/span&gt;&lt;/div&gt;&lt;/li&gt;&lt;li&gt;&lt;div align="justify"&gt;&lt;span style="font-family: arial;"&gt;Locations subject to possible exposure to radioactivity &lt;/span&gt;&lt;/div&gt;&lt;/li&gt;&lt;li&gt;&lt;div align="justify"&gt;&lt;span style="font-family: arial;"&gt;Locations close to power supplies &lt;/span&gt;&lt;/div&gt;&lt;/li&gt;&lt;/ul&gt;&lt;span style="font-family: arial;"&gt;&lt;div align="justify"&gt;&lt;br /&gt;The operating environment of the PLC System can have a large effect on the longevity and reliability of the system. Improper operating environments can lead to malfunction, failure, and other unforeseeable problems with the PLC System. Be sure that the operating environment is within the specified conditions at installation and remains within the specified conditions during the life of the system.&lt;/div&gt;&lt;/span&gt;&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/5812867464294190346-6191861593844008920?l=plc-installation.blogspot.com' alt='' /&gt;&lt;/div&gt;</description><link>http://plc-installation.blogspot.com/2008/03/matters-that-must-be-known-before.html</link><author>noreply@blogger.com (AGUNG)</author><media:thumbnail xmlns:media='http://search.yahoo.com/mrss/' url='http://1.bp.blogspot.com/__O36vLCsD3k/R9YHGFdQtNI/AAAAAAAAACE/zU9uGmekPLM/s72-c/Clip_10.jpg' height='72' width='72'/></item><item><guid isPermaLink='false'>tag:blogger.com,1999:blog-5812867464294190346.post-5667845944910967836</guid><pubDate>Mon, 10 Mar 2008 07:10:00 +0000</pubDate><atom:updated>2010-11-07T22:48:06.024+08:00</atom:updated><title>Planning and preparing the work to install the PLC</title><description>&lt;div align="justify"&gt;&lt;span style="font-family: arial;"&gt;Planning&lt;img alt="" border="0" height="1" src="http://www.assoc-amazon.com/e/ir?t=pi0fa-20&amp;amp;l=btl&amp;amp;camp=213689&amp;amp;creative=392969&amp;amp;o=1&amp;amp;a=0071460373" style="border: medium none ! important; margin: 0px ! important; padding: 0px ! important;" width="1" /&gt; is basic function of management. So that the risk could be minimized, with that all the work, action and policy must be planned beforehand. Planning gives the complete and clear representation about all the work. Planning the work consist of compiles the work plan, plans the equipment and material, and coordinates the work.&lt;br /&gt;&lt;/span&gt;&lt;/div&gt;&lt;div align="justify"&gt;&lt;span style="font-family: Arial;"&gt;&lt;/span&gt;&lt;/div&gt;&lt;div align="justify"&gt;&lt;span style="font-family: arial;"&gt;&lt;b&gt;&lt;/b&gt;&lt;/span&gt;&lt;/div&gt;&lt;div align="justify"&gt;&lt;span style="font-family: arial;"&gt;&lt;b&gt;&lt;/b&gt;&lt;/span&gt;&lt;/div&gt;&lt;div align="justify"&gt;&lt;span style="font-family: arial;"&gt;&lt;b&gt;Compiling a work plan&lt;/b&gt;&lt;br /&gt;Compiling a work plan is an activity to make the sequence of the most efficient work execution steps. In compiling the work plan is given high priority to the parts of easy done beforehand, then difficult shares. There is a lot of method to install the PLC&lt;img alt="" border="0" height="1" src="http://www.assoc-amazon.com/e/ir?t=pi0fa-20&amp;amp;l=btl&amp;amp;camp=213689&amp;amp;creative=392969&amp;amp;o=1&amp;amp;a=0134898400" style="border: medium none ! important; margin: 0px ! important; padding: 0px ! important;" width="1" /&gt;. Under given some guidance can be used to install the PLC. Of course you have to follow the existing Standard Operational Procedure.&lt;br /&gt;&lt;/span&gt;&lt;/div&gt;&lt;div align="justify"&gt;&lt;span style="font-family: arial;"&gt;Step below only represent one of practical example;&lt;/span&gt;&lt;/div&gt;&lt;ul&gt;&lt;li&gt;&lt;span style="font-family: arial;"&gt;Learn the wiring diagram and configuration of the PLC will be installed&lt;/span&gt;&lt;/li&gt;&lt;li&gt;&lt;span style="font-family: arial;"&gt;Learn Installation guide of the PLC &lt;/span&gt;&lt;/li&gt;&lt;li&gt;&lt;span style="font-family: arial;"&gt;Install the CPU Unit and I/O Unit&lt;/span&gt;&lt;/li&gt;&lt;li&gt;&lt;span style="font-family: arial;"&gt;Install the Expansion Unit or Expansion I/O Unit &lt;/span&gt;&lt;/li&gt;&lt;li&gt;&lt;span style="font-family: arial;"&gt;Install I/O devices ( push button&lt;img alt="" border="0" height="1" src="http://www.assoc-amazon.com/e/ir?t=pi0fa-20&amp;amp;l=btl&amp;amp;camp=213689&amp;amp;creative=392969&amp;amp;o=1&amp;amp;a=B001TL79JE" style="border: medium none ! important; margin: 0px ! important; padding: 0px ! important;" width="1" /&gt;, sensor, relay&lt;img alt="" border="0" height="1" src="http://www.assoc-amazon.com/e/ir?t=pi0fa-20&amp;amp;l=btl&amp;amp;camp=213689&amp;amp;creative=392969&amp;amp;o=1&amp;amp;a=B000C83SPE" style="border: medium none ! important; margin: 0px ! important; padding: 0px ! important;" width="1" /&gt;, motor&lt;img alt="" border="0" height="1" src="http://www.assoc-amazon.com/e/ir?t=pi0fa-20&amp;amp;l=btl&amp;amp;camp=213689&amp;amp;creative=392969&amp;amp;o=1&amp;amp;a=B001GBMNS4" style="border: medium none ! important; margin: 0px ! important; padding: 0px ! important;" width="1" /&gt;, etc)&lt;/span&gt;&lt;/li&gt;&lt;li&gt;&lt;span style="font-family: arial;"&gt;Install wire the I/O Unit and I/O devices&lt;/span&gt;&lt;/li&gt;&lt;li&gt;&lt;span style="font-family: arial;"&gt;Install wire the Power Supply &lt;/span&gt;&lt;/li&gt;&lt;li&gt;&lt;span style="font-family: arial;"&gt;Connect communications devices if necessary&lt;/span&gt;&lt;/li&gt;&lt;li&gt;&lt;span style="font-family: arial;"&gt;Connect Programming devices&lt;/span&gt;&lt;/li&gt;&lt;li&gt;&lt;span style="font-family: arial;"&gt;Check I/O wiring&lt;br /&gt;&lt;/span&gt;&lt;/li&gt;&lt;/ul&gt;&lt;span style="font-family: arial;"&gt;&lt;b&gt;&lt;/b&gt;&lt;/span&gt;&lt;br /&gt;&lt;span style="font-family: arial;"&gt;&lt;b&gt;&lt;/b&gt;&lt;/span&gt;&lt;br /&gt;&lt;span style="font-family: arial;"&gt;&lt;b&gt;Planning the work equipment, material, safety equipment, and assistive equipment&lt;/b&gt;&lt;br /&gt;Every assembler process always identify using of the equipment needed and material will be used. &lt;/span&gt;&lt;br /&gt;&lt;span style="font-family: arial;"&gt;The equipment and material required for example:&lt;/span&gt;&lt;br /&gt;&lt;ul&gt;&lt;li&gt;&lt;span style="font-family: arial;"&gt;PLC Unit&lt;/span&gt;&lt;/li&gt;&lt;li&gt;&lt;span style="font-family: arial;"&gt;Tool set &lt;/span&gt;&lt;/li&gt;&lt;li&gt;&lt;span style="font-family: arial;"&gt;Cable&lt;/span&gt;&lt;/li&gt;&lt;li&gt;&lt;span style="font-family: arial;"&gt;I/O devices &lt;/span&gt;&lt;/li&gt;&lt;li&gt;&lt;span style="font-family: arial;"&gt;Box panel&lt;/span&gt;&lt;/li&gt;&lt;li&gt;&lt;span style="font-family: arial;"&gt;Power devices ( MCB, fuse, etc)&lt;/span&gt;&lt;/li&gt;&lt;li&gt;&lt;span style="font-family: arial;"&gt;Safety equipments&lt;/span&gt;&lt;/li&gt;&lt;li&gt;&lt;span style="font-family: arial;"&gt;Coordinates the work&lt;/span&gt;&lt;/li&gt;&lt;/ul&gt;&lt;div align="justify"&gt;&lt;span style="font-family: arial;"&gt;&lt;b&gt;Coordinates the work&lt;/b&gt;&lt;br /&gt;After the work plan is compiled, team member concerned in completion of the task is contacted to ensure that the work has been coordinated effectively so that is not happened the misunderstanding at the time of work execution.&lt;/span&gt;&lt;/div&gt;&lt;div align="justify"&gt;&lt;br /&gt;&lt;span style="font-family: arial;"&gt;While preparing is an activity done before the work is started. Preparing consist of learning installation guide of the PLC, preparing the equipment and material, and preparing the wiring diagram.&lt;/span&gt;&lt;/div&gt;&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/5812867464294190346-5667845944910967836?l=plc-installation.blogspot.com' alt='' /&gt;&lt;/div&gt;</description><link>http://plc-installation.blogspot.com/2008/03/planning-and-preparing-work-to-install.html</link><author>noreply@blogger.com (AGUNG)</author></item><item><guid isPermaLink='false'>tag:blogger.com,1999:blog-5812867464294190346.post-2010890489376874776</guid><pubDate>Mon, 10 Mar 2008 01:39:00 +0000</pubDate><atom:updated>2010-11-07T22:47:01.259+08:00</atom:updated><title>General information about Programmable Logic Controller (PLC)</title><description>&lt;div align="justify"&gt;&lt;span style="font-family: arial;"&gt;&lt;b&gt;What is a Control System?&lt;/b&gt;&lt;br /&gt;A Control System is the electronic equipment needed to control a particular process. It may include everything from a process control computer&lt;img alt="" border="0" height="1" src="http://www.assoc-amazon.com/e/ir?t=pi0fa-20&amp;amp;l=btl&amp;amp;camp=213689&amp;amp;creative=392969&amp;amp;o=1&amp;amp;a=B001O79HNO" style="border: medium none ! important; margin: 0px ! important; padding: 0px ! important;" width="1" /&gt;, if one is used, to the factory computer, down through the PLCs&lt;img alt="" border="0" height="1" src="http://www.assoc-amazon.com/e/ir?t=pi0fa-20&amp;amp;l=btl&amp;amp;camp=213689&amp;amp;creative=392969&amp;amp;o=1&amp;amp;a=B001DIL6WY" style="border: medium none ! important; margin: 0px ! important; padding: 0px ! important;" width="1" /&gt;&lt;img alt="" border="0" height="1" src="http://www.assoc-amazon.com/e/ir?t=pi0fa-20&amp;amp;l=btl&amp;amp;camp=213689&amp;amp;creative=392969&amp;amp;o=1&amp;amp;a=0965944662" style="border: medium none ! important; margin: 0px ! important; padding: 0px ! important;" width="1" /&gt; (and there may be many of them networked together) and then on down through the network to the control components: the switches, stepping motors&lt;img alt="" border="0" height="1" src="http://www.assoc-amazon.com/e/ir?t=pi0fa-20&amp;amp;l=btl&amp;amp;camp=213689&amp;amp;creative=392969&amp;amp;o=1&amp;amp;a=085296417X" style="border: medium none ! important; margin: 0px ! important; padding: 0px ! important;" width="1" /&gt;, solenoids&lt;img alt="" border="0" height="1" src="http://www.assoc-amazon.com/e/ir?t=pi0fa-20&amp;amp;l=btl&amp;amp;camp=213689&amp;amp;creative=392969&amp;amp;o=1&amp;amp;a=B003EBH7ZI" style="border: medium none ! important; margin: 0px ! important; padding: 0px ! important;" width="1" /&gt;, and sensors&lt;img alt="" border="0" height="1" src="http://www.assoc-amazon.com/e/ir?t=pi0fa-20&amp;amp;l=btl&amp;amp;camp=213689&amp;amp;creative=392969&amp;amp;o=1&amp;amp;a=B000KL0MZC" style="border: medium none ! important; margin: 0px ! important; padding: 0px ! important;" width="1" /&gt; which monitor and control the mechanical operations.See the picture below;&lt;br /&gt;&lt;/span&gt;&lt;/div&gt;&lt;div align="justify"&gt;&lt;span style="font-family: arial;"&gt;&lt;/span&gt;&lt;/div&gt;&lt;div align="center"&gt;&lt;a href="http://2.bp.blogspot.com/__O36vLCsD3k/R9SWQ1dQtAI/AAAAAAAAAAc/ujsrZA62uho/s1600-h/blog1.jpg"&gt;&lt;span style="font-family: arial;"&gt;&lt;img alt="" border="0" id="BLOGGER_PHOTO_ID_5175927087727424514" src="http://2.bp.blogspot.com/__O36vLCsD3k/R9SWQ1dQtAI/AAAAAAAAAAc/ujsrZA62uho/s400/blog1.jpg" /&gt;&lt;/span&gt;&lt;/a&gt;&lt;/div&gt;&lt;div align="justify"&gt;&lt;span style="font-family: arial;"&gt;A Control System can involve very large applications where many different models of PLC are networked together or it could be an application as small as a single PLC controlling a single output device.&lt;/span&gt;&lt;/div&gt;&lt;div align="justify"&gt;&lt;span style="font-family: arial;"&gt;&lt;/span&gt;&lt;/div&gt;&lt;div align="center"&gt;&lt;a href="http://2.bp.blogspot.com/__O36vLCsD3k/R9SuJ1dQtCI/AAAAAAAAAAs/t_5GUtWdCF4/s1600-h/Clip.gif"&gt;&lt;span style="font-family: arial;"&gt;&lt;img alt="" border="0" id="BLOGGER_PHOTO_ID_5175953355747406882" src="http://2.bp.blogspot.com/__O36vLCsD3k/R9SuJ1dQtCI/AAAAAAAAAAs/t_5GUtWdCF4/s400/Clip.gif" /&gt;&lt;/span&gt;&lt;/a&gt;&lt;/div&gt;&lt;div align="justify"&gt;&lt;span style="font-family: arial;"&gt;In the typical Control System example shown above, a PLC controls the movement of the workpiece bed across two horizontal axes using Limit Switches and Servomotors to monitor and control movement.&lt;br /&gt;&lt;br /&gt;&lt;b&gt;The Role of the PLC&lt;/b&gt;&lt;br /&gt;The PLC is the part of the Control System that directly controls the manufacturing process. According to the program stored in its memory, the PLC accepts data from the input devices connected to it, and uses this data to monitor the controlled system. When the program calls for some action to take place, the PLC sends data to the output devices connected to it, to cause that action to take place. The PLC may be used to control a simple, repetitive task, or it may be connected to other PLCs, or to a host computer in order to integrate the control of a complex process.&lt;br /&gt;&lt;br /&gt;&lt;b&gt;How Does a PLC Work?&lt;/b&gt;&lt;br /&gt;PLCs operate by monitoring input signals and providing output signals. When changes are detected in the signals, the PLC reacts, through the user-programmed internal logic, to produce output signals. The PLC continually cycles the program in its memory to achieve this control. A program for your applications must be designed, and stored in the PLC. This program is then executed as part of the cycle of internal operations of the PLC.&lt;br /&gt;&lt;br /&gt;&lt;i&gt;Cycle&lt;/i&gt;&lt;br /&gt;When a PLC operates, that is, when it executes its program to control an external system, a series of operations are performed inside the PLC. These internal operations can be broadly classified into the following four categories:&lt;/span&gt;&lt;/div&gt;&lt;span style="font-family: arial;"&gt;&lt;ul&gt;&lt;li&gt;Common (or overseeing) processes, such as watchdog timer operation and testing the program memory&lt;/li&gt;&lt;li&gt;Data input and output&lt;/li&gt;&lt;li&gt;Instruction execution&lt;/li&gt;&lt;li&gt;Peripheral device servicing&lt;/li&gt;&lt;/ul&gt;&lt;div align="justify"&gt;&lt;i&gt;Cycle Time&lt;/i&gt;&lt;br /&gt;The total time required for a PLC to perform all these internal operations is called the cycle time. The flowchart and diagram on the following page illustrate these internal operations for a typical PLC. Timing is one of the most important factors in designing a Control System. For accurate operations, it is necessary to have answers to such questions as these:&lt;/div&gt;&lt;ul&gt;&lt;li&gt;How long does it take for the PLC to execute all the instructions in its memory?&lt;/li&gt;&lt;li&gt;How long does it take for the PLC to produce a control output in response to a given input signal?&lt;/li&gt;&lt;/ul&gt;&lt;div align="justify"&gt;The cycle time of the PLC can be automatically calculated and monitored, but it is necessary to have an understanding of the timing relationships within the PLC for effective System design and programming.For example, see the flowchart below;&lt;/div&gt;&lt;/span&gt;&lt;br /&gt;&lt;div align="justify"&gt;&lt;span style="font-family: arial;"&gt;&lt;/span&gt;&lt;/div&gt;&lt;div align="center"&gt;&lt;a href="http://3.bp.blogspot.com/__O36vLCsD3k/R9SxUFdQtDI/AAAAAAAAAA0/_xsGgC9_750/s1600-h/Clip_2.gif"&gt;&lt;span style="font-family: arial;"&gt;&lt;img alt="" border="0" height="422" id="BLOGGER_PHOTO_ID_5175956830375949362" src="http://3.bp.blogspot.com/__O36vLCsD3k/R9SxUFdQtDI/AAAAAAAAAA0/_xsGgC9_750/s400/Clip_2.gif" width="286" /&gt;&lt;/span&gt;&lt;/a&gt;&lt;/div&gt;&lt;div align="justify"&gt;&lt;/div&gt;&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/5812867464294190346-2010890489376874776?l=plc-installation.blogspot.com' alt='' /&gt;&lt;/div&gt;</description><link>http://plc-installation.blogspot.com/2008/03/general-information-about-programmable.html</link><author>noreply@blogger.com (AGUNG)</author><media:thumbnail xmlns:media='http://search.yahoo.com/mrss/' url='http://2.bp.blogspot.com/__O36vLCsD3k/R9SWQ1dQtAI/AAAAAAAAAAc/ujsrZA62uho/s72-c/blog1.jpg' height='72' width='72'/></item><item><guid isPermaLink='false'>tag:blogger.com,1999:blog-5812867464294190346.post-6750004572701006544</guid><pubDate>Mon, 10 Mar 2008 01:07:00 +0000</pubDate><atom:updated>2010-11-07T22:45:46.100+08:00</atom:updated><title>Introduction</title><description>&lt;div align="justify"&gt;&lt;span style="font-family: arial;"&gt;My article in this time explains how to install a Programmable Logic Controller&lt;img alt="" border="0" height="1" src="http://www.assoc-amazon.com/e/ir?t=pi0fa-20&amp;amp;l=btl&amp;amp;camp=213689&amp;amp;creative=392969&amp;amp;o=1&amp;amp;a=0073510882" style="border: medium none ! important; margin: 0px ! important; padding: 0px ! important;" width="1" /&gt; (PLC). This article I compile in 5 titles. &lt;/span&gt;&lt;span style="color: red; font-family: arial;"&gt;To see the picture on this article more detail, you can access on the picture.&lt;/span&gt;&lt;br /&gt;&lt;span style="font-family: arial;"&gt;&lt;b&gt;&lt;/b&gt;&lt;/span&gt;&lt;/div&gt;&lt;div align="justify"&gt;&lt;span style="font-family: arial;"&gt;&lt;b&gt;Title 1 : General information about PLC&lt;/b&gt;&lt;br /&gt;General information about Programmable Logic Controller (PLC), what a Programmable Logic Controller(PLC) can do and how a Programmable Logic Controller works is provided.&lt;/span&gt;&lt;br /&gt;&lt;span style="font-family: arial;"&gt;&lt;b&gt;&lt;/b&gt;&lt;/span&gt;&lt;/div&gt;&lt;div align="justify"&gt;&lt;span style="font-family: arial;"&gt;&lt;b&gt;Title 2 : Planning and preparing the work to install the PLC&lt;/b&gt;&lt;br /&gt;Explains about the matters that must be planned and prepared before installing the PLC such as planning the work, planning and preparing the equipment and material, coordinates the work, etc.&lt;/span&gt;&lt;br /&gt;&lt;span style="font-family: arial;"&gt;&lt;b&gt;&lt;/b&gt;&lt;/span&gt;&lt;/div&gt;&lt;div align="justify"&gt;&lt;span style="font-family: arial;"&gt;&lt;b&gt;Title 3 : Matters that must be known before installing the PLC&lt;/b&gt;&lt;br /&gt;Explains about the matters that must be known before installing the PLC such as safety procedure, hardware of the PLC and the necessary environmental conditions for installing the PLC.&lt;/span&gt;&lt;br /&gt;&lt;span style="font-family: arial;"&gt;&lt;b&gt;&lt;/b&gt;&lt;/span&gt;&lt;/div&gt;&lt;div align="justify"&gt;&lt;span style="font-family: arial;"&gt;&lt;b&gt;Title 4 : Steps for installing the PLC&lt;/b&gt;&lt;br /&gt;Explains about steps for installing the PLC such as panel/cabinet installation, installing the CPU Unit and I/O Unit, installing the Expansion Unit, installing I/O devices, wiring and connections. &lt;/span&gt;&lt;br /&gt;&lt;span style="font-family: arial;"&gt;&lt;b&gt;&lt;/b&gt;&lt;/span&gt;&lt;/div&gt;&lt;div align="justify"&gt;&lt;span style="font-family: arial;"&gt;&lt;b&gt;Title 5 : Checking the work and making the report&lt;br /&gt;&lt;/b&gt;Explains abouts checking the work and making the report such as inspecting installation, testing installation and making the report&lt;/span&gt;&lt;/div&gt;&lt;div align="justify"&gt;&lt;span style="font-family: Arial; font-size: 78%;"&gt;&lt;/span&gt;&lt;/div&gt;&lt;span style="font-family: Arial; font-size: 78%;"&gt;&lt;/span&gt;&lt;br /&gt;&lt;span style="font-family: arial; font-size: 78%;"&gt;Reference;&lt;/span&gt;&lt;br /&gt;&lt;ul&gt;&lt;li&gt;&lt;div align="justify"&gt;&lt;span style="font-family: arial; font-size: 78%;"&gt;Installation guide of the Omron PLC&lt;/span&gt;&lt;/div&gt;&lt;/li&gt;&lt;li&gt;&lt;div align="justify"&gt;&lt;span style="font-family: arial; font-size: 78%;"&gt;Installation guide of the LG PLC&lt;/span&gt;&lt;/div&gt;&lt;/li&gt;&lt;li&gt;&lt;div align="justify"&gt;&lt;span style="font-family: arial; font-size: 78%;"&gt;"PLC Installation" ; Training module of Department of Labour and Transmigration of Indonesia&lt;/span&gt;&lt;/div&gt;&lt;/li&gt;&lt;/ul&gt;&lt;b&gt;&lt;span style="font-family: arial;"&gt;&lt;/span&gt;&lt;/b&gt;&lt;br /&gt;&lt;div align="left"&gt;&lt;b&gt;&lt;span style="font-family: arial;"&gt;&lt;/span&gt;&lt;/b&gt;&lt;/div&gt;&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/5812867464294190346-6750004572701006544?l=plc-installation.blogspot.com' alt='' /&gt;&lt;/div&gt;</description><link>http://plc-installation.blogspot.com/2008/03/introduction_09.html</link><author>noreply@blogger.com (AGUNG)</author></item></channel></rss>
